FIRE ALARM CONTROL PANEL

e.syline, the line of electronic water pressure booster systems that
redefines the rules of residential water pressurization.

M1.1

LE-FN-4127 Fire Alarm Control Panel

  • UL 864 9th edition Listed
  • 2 loop (LE-FN-2127 Series) or 4 loop (LE-FN-4127 Series) versions
  • Analog design using advanced DCP protocol for fast and robust communication
  • Up to 127 sensors & modules, plus 127 analog sounder bases, for a total of 254 points possible per loop
  • Uses standard wire, no shielded or twisted pair required on SLC loops
  • Supports Class B (style 4) and Class A (style 6 or 7) SLC loops
  • 4 on board Class B (style Y) NAC circuits rated at 2.5 Amps each
  • Programmable sensitivity levels per device & automatic day/night sensitivity modes
  • Automatic daily calibration & drift compensation routine
  • Large 8-line x 40-character LCD display (320 char.)
  • Dual RS-485 bus for panel network
  • 2 built-in RS-232 interfaces for programming via a PC and serial printer interface
  • 5 on board programmable Form C relays rated at 1 amp at 30VDC (Fire1, Fire2, trouble, supervisory, aux.)
  • 500mA of auxiliary power available rated at 24 VDC
  • Loop Explorer Windows® configuration utility
  • 500 network wide software zones
  • Network Capability of up to 64 panels
  • RS485 slave bus for expansion – up to 32 LE-FN-4127-IO boards or up to 15 LE- FN-LCD-S serial annunciators and up to 17 LE-FN-4127-IO boards
  • Auto-learn feature
  • Fire Drill test function
  • Walk Test function
  • Alarm Verification feature
  • Operates on 120VAC or 240VAC input voltage
  • Powerful & versatile Cause & Effect programming (up to 500 maximum, network wide) including:
  • Cause & Effect action
  • Disable function configuration
  • Test mode configuration

Description

The EAGLE SERIES control panel is an analog addressable fire alarm panel containing 2 or 4 SLC loops with each loop supporting 127 devices of any combination (sensors or modules), and 127 analog sounder bases, for a possible total of 254 points.

Communication between devices is transferred through standard cable (shielded or twisted pair is not required). Each panel includes a 5.25 amp power supply and has 4 on board NAC circuits. An RS-485 bus provides communication to the panel network, while the RS-232 interface allows the convenience of programming via a PC.

The system will support a variety of devices: photo, ion and heat sensors, which contain a unique, patented sensor design incorporating automatic drift compensation and day/night sensitivity mode. Additional devices include contact monitors, relay controllers, supervised auxiliary output and short circuit isolator modules. In addition, interfaces to conventional detection systems can be established by using a conventional zone-monitoring module.

The Loop Explorer Windows® Software interface provides the installer with fingertip access to installation programming and diagnostic tools.

An Auto-learn feature offers the convenience for quick start applications. Add to this a reputation for high quality and dedicated service makes this an exceptional product both in performance and value.

M1.1

LE-FN-2127 – Fire Alarm Control Panel

Features

  • UL 864 9th edition Listed
  • 2 loop (LE-FN-2127 Series) or 4 loop (LE-FN-4127 Series) versions
  • Analog design using advanced DCP protocol for fast and robust communication
  • Up to 127 sensors & modules, plus 127 analog sounder bases, for a total of 254 points possible per loop
  • Uses standard wire, no shielded or twisted pair required on SLC loops
  • Supports Class B (style 4) and Class A (style 6 or 7) SLC loops
  • 4 on board Class B (style Y) NAC circuits rated at 2.5 Amps each
  • Programmable sensitivity levels per device & automatic day/night sensitivity modes
  • Automatic daily calibration & drift compensation routine
  • Large 8-line x 40-character LCD display (320 char.)
  • Dual RS-485 bus for panel network
  • 2 built-in RS-232 interfaces for programming via a PC and serial printer interface
  • 5 on board programmable Form C relays rated at 1 amp at 30VDC (Fire1, Fire2, trouble, supervisory, aux.)
  • 500mA of auxiliary power available rated at 24 VDC
  • Loop Explorer Windows® configuration utility
  • 500 network wide software zones
  • Network Capability of up to 64 panels
  • RS485 slave bus for expansion – up to 32 LE-FN-4127-IO boards or up to 15 LE- FN-LCD-S serial annunciators and up to 17 LE-FN-4127-IO boards
  • Auto-learn feature
  • Fire Drill test function
  • Walk Test function
  • Alarm Verification feature
  • Operates on 120VAC or 240VAC input voltage
  • Powerful & versatile Cause & Effect programming (up to 500 maximum, network wide) including:
  • Cause & Effect action
  • Disable function configuration
  • Test mode configuration

Description

The EAGLE SERIES control panel is an analog addressable fire alarm panel containing 2 or 4 SLC loops with each loop supporting 127 devices of any combination (sensors or modules), and 127 analog sounder bases, for a possible total of 254 points.

Communication between devices is transferred through standard cable (shielded or twisted pair is not required). Each panel includes a 5.25 amp power supply and has 4 on board NAC circuits. An RS-485 bus provides communication to the panel network, while the RS-232 interface allows the convenience of programming via a PC.

The system will support a variety of devices: photo, ion and heat sensors, which contain a unique, patented sensor design incorporating automatic drift compensation and day/night sensitivity mode. Additional devices include contact monitors, relay controllers, supervised auxiliary output and short circuit isolator modules. In addition, interfaces to conventional detection systems can be established by using a conventional zone-monitoring module.

The Loop Explorer Windows® Software interface provides the installer with fingertip access to installation programming and diagnostic tools.

An Auto-learn feature offers the convenience for quick start applications. Add to this a reputation for high quality and dedicated service makes this an exceptional product both in performance and value.

LCD ANNUNCIATOR

e.syline, the line of electronic water pressure booster systems that
redefines the rules of residential water pressurization.

M1.2

LE-FN-LCD-S Serial annunciator

Features

  • UL 864 9th edition Listed
  • Large 320 character liquid crystal display (8 line x 40 character) allows viewing of system status
  • LED indicators for Fire, Supervisory Alarm, Pre-Alarm, Fire Output Active, AC Power On, On Test, Panel Sounder Silenced, Delay Active, More Events, Point Bypassed, General Trouble, Power Trouble, System Trouble & NAC Trouble
  • Same controls as the EAGLE fire panel (Reset, Panel Sounder Silence, Lamp Test, Alarm Silence, Re-sound Alarm, Fire Drill, Programmable Function, More Events, More Fire Events, Enter & Exit)
  • Up to 15 LE-FN-LCD-S serial annunicators may be connected to a FireNET control panel or network annunciator
  • Resides on the FireNET slave RS-485 line
  • Local piezo sounder for event notification
  • Supports user codes & firefighter key to enable access & controls
  • Powered by EAGLE Aux 24VDC or UL fire listed Aux. 24VDC supply
  • Available in red or charcoal, and can be surface or flush mounted
  • Built-in help & alarm information screens
  • Fire drill function

Description

The LE-FN-LCD-S serial annunciator provides a convenient and cost effective remote annunciator solution. Up to 15 LE-FN-LCD-S annunciators can be connected to the slave RS-485 port of the FireNET control panel or network annunciator. The LE-FN-LCD-S’s large 320 character display and navigation buttons are a complete mimic of the FireNET control panel display. The use of a common interface allows the user to easily operate the LE-FN-LCD-S as if he were operating the FireNET control panel directly. Security is established by the use of a password or firefighters enable key. Designed to be aesthetically pleasing, the LE-FN-LCD-S is available in charcoal grey or red enclosures. The LE-FN-LCD-S can be surface or flush mounted without the need for a trim ring. The contractor shall furnish and install where indicated on the plans, the serial remote annunciator model LE-FN-LCD-S. The LE-FN-LCD-S shall connect to the FireNET fire alarm control panel (FACP) or network annunciator (LE-FN-LCD-N) RS485 slave bus. The serial remote annunciator shall annunciate on its 320 character display and local buzzer, the condition of its master FireNET FACP. Up to 15 LE-FN-LCD-S serial annunciators may be connected together on a single RS-485 FireNET slave bus. The LE-FN-LCD-S shall be UL listed and compatible with the FireNET control panel, and have surface or flush mount capability.

M1.3

LE-FN-LCD-N Network Annunciator

Features

  • UL 864 9th edition Listed
  • 320 character liquid crystal display (8 line x 40 character)
  • LED indicators for Fire, Supervisory Alarm, Pre-Alarm, Fire Output Active, Power On, On Test, Panel Sounder Silenced, Delay Active, More Events, Point Bypassed, General Trouble, Power Trouble, System Trouble & NAC Trouble
  • Dual RS485 ports for primary fire network
  • RS485 slave bus for expansion – up to 32 LE-FN-4127-IO boards or up to 15 LE-FN-LCD-S serial annunciators and up to17 LE-FN-4127-IO boards
  • 2 built-in RS-232 interfaces for programming via a PC and serial printer interface
  • 4 on board programmable Form C relays rated at 1 Amp at 30VDC (Fire, Supervisory, Trouble & Auxiliary)
  • Same controls as the EAGLE fire panel (Reset, Panel Sounder Silence, Lamp Test, Alarm Silence, Re-sound Alarm, Fire Drill, Programmable Function, More Events, and More Fire Events, Enter & Exit)
  • Local piezo sounder for event notification
  • Supports user codes & firefighter key to enable access & controls
  • Powered by EAGLE Aux 24VDC or UL fire listed Aux. 24VDC supply
  • Available in red or charcoal, and can be surface or flush mounted (using trim ring)
  • True network annunciator, any or all panels can be routed to the LE-FN-LCD-N. In addition, each event category can be individually routed to the LE-FN-LCD-N
  • Up to (64) EAGLE panels & LE-FN-LCD-N’s can be networked together in any combination
  • 500mA of auxiliary power available rated at 24VDC
  • Auto-learn feature
  • Built-in help & alarm information screens
  • Fire drill function
  • Each LE-FN-LCD-N is completely independent
  • The LE-FN-LCD-N can be configured to remote reset, silence, resound, any or all panels on the network in any combination

Description

The LE-FN-LCD-N type LCD network annunciator is designed to be used with the EAGLE addressable system. It allows for remote access, monitoring & control of the

EAGLE system throughout the building. The LE-FN-LCD-N is a true network annunciator that can access, monitor & control any or all EAGLE panels in the network. Each LE-FN-LCD-N is completely independent. The highly intuitive user interface and 320 character LCD display of the LE-FN-LCD-N is exactly the same as the EAGLE panel.

ADDRESSABLE DETECTORS

e.syline, the line of electronic water pressure booster systems that
redefines the rules of residential water pressurization.

M1.4

Photoelectric Smoke Detector – LE-ALN-V

Features

  • Low profile – only 2.00″ high, including base
  • Simple and reliable device addressing
  • Automatic compensation for sensor contamination
  • Built-in fire test feature
  • Uses the noise-immune Digital Communication Protocol (DCP), which utilizes interrupts for fast response to fires
  • Two built-in power/alarm LEDs
  • Programmable non-polling LEDs
  • Non-directional smoke chamber
  • Vandal resistant security locking feature
  • Removable smoke labyrinth for cleaning or replacement

Description

The LE-ALN-V Photoelectric Smoke Sensor is particularly suited to detecting optically dense smoke typical of fires involving materials such as soft furnishings, plastic, foam or other similar materials which tend to smolder and produce large visible smoke particles. unique design allows fast response to flaming fires as well as smoldering fires while eliminating false alarms.

M1.5

Heat Detector – LE-ATJ-EA

Features

  • Low profile – only 2.00″ high, including base
  • Simple and reliable device addressing method
  • Uses the noise immune Digital Communication Protocol (DCP), which utilizes interrupts for fast response to fires
  • Rate of rise temperature threshold = 15°F/Min (determined by panel)
  • Adjustable threshold temperature = 135°F – 190°F (determined by panel)
  • UL maximum spacing of 70 feet

Description

The LE-ATJ-EA Sensor provides accurate temperature measurement data to the fire alarm control panel. This sensor is particularly suited to environments where smoke detectors are unsuitable because of the presence of system or cooking fumes such as in a kitchen.

M1.6

Multi-criteria Detector – LE-ACC-V

Features

  • Low Profile – Only 2” high, including base
  • Simple and reliable device addressing method
  • Automatic compensation for sensor contamination
  • Built-in fire test feature
  • Uses the noise immune Digital Communication Protocol (DCP), which utilizes interrupts for fast response to fires
  • Two built-in power/alarm LED’s
  • Non-directional smoke chamber
  • Vandal resistant security locking feature
  • Removable smoke labyrinth for cleaning or replacement

Description

The LE-ACC-V Multi-Criteria Smoke Sensor is particularly suited for detecting smoke produced by a wide range of combustibles found in various applications. Temperature monitoring is achieved by a thermistor placed for optimum sensitivity. unique design allows fast response to flaming fires as well as smoldering fires while minimizing false alarms.

ADDRESSABLE DETECTOR BASES

e.syline, the line of electronic water pressure booster systems that
redefines the rules of residential water pressurization.

M1.7

Analog Detector Base 4” & 6” – LE-YBN-NSA-4 & LE-HSB-NSA-6

Features

  • UL Listed
  • Designed for use with all LE-NS analog sensors
  • Available in 4 and 6 inch models
  • Contains a security locking tab for tamper protection

Description

The LE-YBN-NSA-4 and LE-HSB-NSA-6 are designed specifically for use with the LE-NS Analog models LE-ALN-V, LE-ATJ-EA, and LE-ACC-V.

The LE-YBN-NSA-4 and LE-HSB-NSA-6 common mounting bases allows for complete compatibility for all of the NS Series Analog sensors. The bases are lightweight and very thin, providing a low profile once installed. The solder-less screw terminals enable quick and easy wiring connections.

M1.8

Analog Sounder Base – LE-ASB

Features

  • Programmable evacuation codes – Continuous, March, ANSI Temporal patterns
  • Base learns the sensor address and assumes an upper range address (128-254)
  • Up to 127 sensors and 127 ASBs can be used on one SLC loop
  • Can be alarmed or reset by zone or by individual address
  • LE-ASB SLC loop wire resistance = 50 ohms Max. (Total SLC wire run length)
  • High sound pressure level (85dB SPL at 10 feet)

Description

The LE-ASB Analog Sounder Base is designed for use with analog sensors LE-ALN-V, LE-ATJ-EA, and LE-ACC-V. Each addressable base is to be connected to a Eagle DCP Signalling Line Circuit (SLC). The LE-ASB provides an audible alarm in the immediate vicinity. Typical applications are hotels, apartments, and hospitals.

CONVENTIONAL DETECTORS

e.syline, the line of electronic water pressure booster systems that
redefines the rules of residential water pressurization.

M1.9

Photoelectric Smoke Detector – LE-SOC-24V

Features

  • Computer-designed non-directional smoke chamber
  • 360° view of detector status LED
  • Low profile, 1.8″ high (with base)
  • 2 or 4 wire base compatibility, relay bases available
  • Highly stable operation, RF/Transient protection
  • Low standby current, 59μA at 24VDC
  • Two built-in power/sensitivity supervision/alarm LEDs
  • Automatic Sensitivity window verification function meets outlined requirements in NFPA 72, Chapter 2 & 7, Inspection, Testing and Maintenance.

Description

The LE-SOC-24V photoelectric smoke detector utilizes two bicolored LEDs for indication of status. In a normal standby condition the LEDs flash Green every 3 seconds. When the detector senses that its sensitivity has drifted outside the UL listed sensitivity window the LEDs will flash Red every 3 seconds. When the detector senses smoke and goes into alarm the status LEDs will latch on Red. The detector utilizes an infrared LED light source and silicon photo diode receiving element in the smoke chamber. In a normal standby condition, the receiving element receives no light from the pulsing LED light source. In the event of a fire, smoke enters the detector smoke chamber and light is reflected from the smoke particles to the receiving element. The light received is converted into an electronic signal. Signals are processed and compared to a reference level, and when two consecutive signals exceeding the reference level are received within a specified period of time, the time delay circuit triggers the SCR switch to activate the alarm signal. The status LEDs light continuously during the alarm period

M1.10

Photoelectric Smoke Detector – LE-SOC-24V

Features

  • Low profile, 1.8″ high (with base)
  • 2 or 4 wire base compatibility, relay bases available
  • Highly stable operation, RF/Transient protection
  • Low standby current, 45μA at 24VDC
  • Air velocity range 0-300 fpm
  • Two built-in power/sensitivity supervision/alarm LEDs
  • Non-directional smoke chamber
  • Removable smoke labyrinth for cleaning or replacement
  • Automatic Sensitivity window verification function meets outlined requirements in NFPA 72, Chapter 2 & 7, Inspection, Testing and Maintenance.
  • Compatible with LE-SIJ-24 ionization detectors

Description

The LE-SLV-24N photoelectric smoke detector utilizes two bicolored LEDs for indication of status. In a normal standby condition the LEDs flash Green every 3 seconds. When the detector senses that its sensitivity has drifted outside the UL listed sensitivity window the LEDs will flash Red every 3 seconds. When the detector senses smoke and goes into alarm the status LEDs will latch on Red.

M1.11

Heat Detector (FT/ROR) – LE-DCD-135/190

Features

  • Choice of fixed temperature/rate-of-rise 135°F or 190°F heat detector
  • UL Listed spacing up to 60′ by 60′
  • 2 or 4 wire base compatibility, relay bases available
  • Highly stable operation, RF/Transient protection
  • Low standby current, 35μA nominal
  • Two built-in power/alarm LED’s for 360° viewing
  • Fully electronic operation
  • Power/alarm LED’s confirm detector status

Description

The LE-DCD-135/-190 fixed temperature/rate-of-rise heat detectors are suited to detect in the presence of slow or fast rising temperatures due to burning combustibles. The construction of these models incorporate a thermistor heat element protected from damage by the built-in, durable plastic guard. These electronic heat detectors incorporate two power/alarm LED’s for 360° indication of status. In standby condition the power LED’s flash Green. In an alarm condition the LED’s latch on Red. The LE-DCD-135/-190 electronic heat detection circuitry performs the same function as a Mechanical Device but with Electronic Precision. If the heat rise is less than 12°/minute the LE-DCD will not alarm until it reaches its alarm temperature (135° or 190° ± 7.5°F). If the heat rise is greater than 12°/minute the DCD will alarm immediately giving an early warning signal and latching the Red alarm LED’s on.

M1.12

Heat Detector (FT) – LE-DFE-135/190

Features

  • Choice of fixed temperature – 135°F or 190°F
  • UL Listed ceiling spacing of 50′ by 50′ (2,500 square feet)
  • Self-Restoring
  • Heat element protected by a built-in guard
  • Contact Rating of 100 mA
  • Highly Dependable
  • Latching LED base available

Description

The LE-DFE 135/190 fixed temperature heat detector is suited to alarm in the presence of slowly rising temperatures. The construction of this model incorporates an oversized heat collector protected from damage by the built-in, durable plastic guard. The LE-DFE-135/190 fixed temperature heat detector used the proven snap-disc principle of operation. This bi-metal disc deflects when temperature reaches a predetermined value. The disc deflection then causes a push-rod to close the internal contact resulting in an alarm condition. The bi-metal disc returns to its normal shape when the heat subsides causing internal contacts to return to their normally open position. A standby condition is restored.

M1.13

Heat Detector (ROR) – LE-DSC-EA

Features

  • The LE-DSC features a slim design which combines visual appeal with a high standard of reliability.
  • The design of the LE-DSC enables the detector to operate in locations where the temperature is likely to increase suddenly should a fire develop.
  • The operating characteristics of LE-DSC is a key feature of the product enabling a very cost effective solution for the use of heat detectors. This detector consumes no current in standby, which enables an unlimited number of detectors to be connected on the same detection wires.
  • With connection to the standard range of conventional bases, the LE-DSC heat detector can be connected or disconnected very easily, allowing simple interchangeability with other members of the conventional detectors.

Description

The LE-DSC rate of rise heat detectors are composed of an air chamber, vent and a flexible metal diaphragm. When the LE-DSC is heated, the air in the chamber expands. The vent permits the chamber to breathe and slowly release the expanded air. If a fire occurs, the air in the chamber will expand more rapidly than it can be vented. This causes the diagram to close a set of precious metal contacts (normally open) to trigger the alarm signal.

M1.14

Multi-criteria Detector – LE-SLR-24H

Features

  • Low profile, 2.2″ high (with base)
  • 2 or 4 wire base compatibility, relay bases available
  • 135°F Fixed Temperature heat sensor (Latching)
  • Heat sensor protected by a built-in guard
  • Highly stable operation, RF/Transient protection
  • Low standby current, 45μA at 24VDC
  • Two built-in power/sensitivity supervision/alarm LED’s
  • Non-directional smoke chamber
  • Vandal resistant security locking feature
  • Removable smoke labyrinth for cleaning or replacement
  • Automatic Sensitivity window verification function meets outlined requirements in NFPA 72, Chapter 2 & 7, Inspection, Testing and Maintenance

Description

The LE-SLR-24H Multi-criteria detector utilizes two bicolored LED’s for indication of status. In a normal standby condition the LED’s flash Green every 3 seconds. When the detector senses that its sensitivity has drifted outside the UL listed sensitivity window the LED’s will flash Red every 3 seconds. When the detector senses smoke and goes into alarm the status LED’s will latch on Red.

M1.15

Multi-criteria Detector – LE-SLR-24H

Features

  •  Low Profile – Only 2.0″ high, including base
  • Simple and reliable device addressing method
  •  Automatic compensation for sensor contamination
  •  Built-in fire test feature
  • Uses the noise immune Digital Communication Protocol (DCP), which utilizes interrupts for fast response to fires
  • Two built-in power/alarm LED’s
  • Programmable Non-polling LED’s
  • Non-directional smoke chamber
  • Vandal resistant security locking feature
  • Removable smoke labyrinth for cleaning or replacement
  • Compatible with the LE-AIE-EA ionization detector, LE-ALG-V Photoelectric detector & the LE-ATG-EA heat detector
  • Smoke chamber design reduces the susceptibility to nuisance alarms caused by steam.

Description

The detection chamber consists of a light emitting diode (LED) and photodiode arrangement. The chamber is designed such that light emitted by the LED cannot normally reach the photo diode. In the event of fire, particles of smoke enter the chamber and scatter the light. As the smoke level increases, the scattering effect increases, causing more light to hit the photo- diode. The chamber contains a unique baffle design which allows smoke to enter the chamber while preventing external light from affecting then photodiode. The photodiode input level is sampled to sense smoke density. When the smoke density exceeds a preset threshold the sensor transmits an interrupt to the fire control panel indicating a fire condition. The fire alarm control panel can adjust the sensor threshold to compensate for contamination.

CONVENTIONAL DETECTORS BASES

e.syline, the line of electronic water pressure booster systems that
redefines the rules of residential water pressurization.

m1.16

Conventional Detector Bases – LE-NS6/LE-NS4/LE-HSC Series

Description

The LE-NS6 and LE-NS4 Series is designed specifically for use with Conventional ModelsLE-SLR-24V Photoelectric Smoke Detector, LE-SLR-24H Photoelectric with Heat Smoke Detector and LE-DCD-135/190 Fixed Temperature/Rate-of-Rise Heat Detector. The Base is an electronics free 6” or 4” base featuring a plastic tamper-lock lug. Each base is equipped with a resistor. Refer to the Datasheet for additional specifications. The LE-NS4 base is a 4” version of the LE-NS6 base.

Models LE-HSC-224R, LE-HSC-220R and the LE-HSC-221R are designed specifically for use with the Conventional Models LE-SLR-24V, LE-SLR-24H or LE-DCD-135/190. The LE-HSC-(X) R series is a 6” base with two sets of Form “C” relay contacts. Models LE-HSC-224R, LE-HSC-220R and the LE-HSC-221R are also approved for use with Conventional Model LE-DFE 135/190.

The LE-HSC-4R is designed specifically for 24 volt 4 wire applications using Conventional Models LE-SIJ-24, LE-SLR-24V, LE-SLR-24H or LE-DCD-135/190. The 6” diameter base is current limited. Relay contact place a direct short occurs across the loop when the detector is actuated. Model LE-HSC-4R is also approved for use with previous Conventional Model LE-DFE 135/190.

The LE-HSC-L Base Series is designed specifically for use with the Fixed Temperature Heat Detectors Models LE-DFE-135/ 190. The LE-HSC-L Series is a 6″ base featuring a current limiting resistor, latching annunciator output and a latching circuit so the alarm LED will remain lit until the control panel has been reset.

m1.17

Sounder Base – LE-SBC

Features

  • Wide operating voltage.
  • Selectable Evacuation Codes: continuous or temporal.
  • Three different configurations: individual, group, and global modes.
  • High sound pressure level (85 dB at 10 ft.)
  • Can be configured to satisfy a wide variety of applications.
  • Available with or without relay, 2 and 4 wire configurations, and bone or white color.

Description

The Models LE-SBC Conventional Sounder Base Series are designed specifically for use with NS conventional style smoke detectors Models LE-SIJ-24 Ionization Smoke Detector, LE-SLR-24V Photoelectric Smoke Detector. The LE-SBC Series will provide an audible evacuation signal (continuous or temporal Code) upon detector alarm. Easily configured to 12 or 24-volt applications through use of a dipswitch, the bases can also be configured to activate in individual, group, or global modes. The relay base model LE-SBC-2R contains two sets of Form “C” Relay Contacts rated at 1 Amps @ 28VDC or 0.5 Amps @ 120VAC. All models come in 6” diameter size.

DUCT DETECTORS

e.syline, the line of electronic water pressure booster systems that
redefines the rules of residential water pressurization.

m1.18

Conventional Detector Bases – LE-NS6/LE-NS4/LE-HSC Series

Features

  • Detects and limits the spread of smoke throughout building HVAC ducts
  • Compatible with building automation and fire alarm systems
  • Installs quickly and easily
  • No screens or filters to clean
  • Rugged gray steel back box with clear cover
  • Accessories – Remote LED alarm indication capability (LE-DH-99-AR only)
  • Meets UL 268A Requirements

Description

The LE-DH-99 is designed and built to meet all local requirements, as well as the NFPA regulations regarding duct smoke detectors. The LE-DH-99-AR is provided with output terminals for remote accessories such as a horn, strobe, remote status indicators and reset key switches or push buttons. Air sampling is accomplished by two tubes which protrude into the duct. An exhaust tube of one standard length (7.5″) is supplied in the installation kit with the smoke duct unit. Once the duct width has been determined the air intake sampling tubes must be ordered. Sampling tubes are supplied in three standard lengths 2.5 ft., 5 ft. and 10 ft. and cut to size to fit the duct.

m1.19

Conventional Duct Detector – LE-DH-98

Features

  • Detects and limits the spread of smoke throughout building HVAC ducts
  • Ability to interconnect (all relays operate with a single alarm) up to 30 units using the same independent power supply
  • Compatible with building automation and fire alarm systems
  • Installs quickly and easily
  • Interchangeable “Plug-In” photoelectric or ionization heads
  • No screens or filters to clean
  • Cover provides magnet window and placement guide for operational testing without disassembly
  • Rugged gray steel back box with clear cover
  • Accessories – Remote power, remote alarm indication capability and remote, horn/piezo capability
  • Meets UL 268A Requirements

Description

The LE-DH-98 Duct Smoke Detector provides early detection of smoke and products of combustion present in air moving through HVAC ducts in Commercial, Industrial and Residential applications. The LE-DH-98 is designed to prevent the recirculation of smoke in areas by the air handling systems, fans and blowers. Complete systems may be shut down in the event of smoke detection. The LE-DH-98-I and the LE-DH-98-P operate on 115 VAC, 24 VAC and 24 VDC respectively and the LE-DH-98 operate on 230 VAC, 24 VAC and 24 VDC.

The LE-DH-98 is designed and built to meet all local requirements, as well as the NFPA regulations regarding duct smoke detectors. Output terminals are provided for remote accessories such as a horn, strobe, remote status indicators and reset key switches or push buttons.

CONVENTIONAL MANUAL PULL STATION

e.syline, the line of electronic water pressure booster systems that
redefines the rules of residential water pressurization.

m1.28

Single Dual Action and Explosion Proof Manual Non-Coded Pull Station

Features

  • Metal Construction
  • Enclosed switch with glass rod (included)
  • 10 Amps @ 120 VAC
  • Available in: Single Action & Dual Action
  • UL Listed

Description

Models LE-HPS series pull stations are available in three models:

  • LE-HPS-SAH single action with Hex lock
  • LE-HPS-DAH dual action with Hex lock
  • LE-HPS-SA-EX-WP Explosion proof

Each model is constructed of a solid die cast housing and comes in glossy red. The back switch plate is plated steel. The electrical switch is rated for 10 Amps @ 120 VDC normally open contact rating. All models are connected via terminal block connections.

M1.29

Weatherproof Manual Pull Station – LE- HPS-SAH-WP

Features

  • Weatherproof Manual Pull Station
  • 10 A, 120 VAC contacts
  • Rugged die-cast aluminium housing and back box
  • Neoprene sealing gasket
  • Corrosion-resistant construction
  • KEY reset
  • Lift and Latching pull-down lever
  • Enclosed switch with glass rod (Included)
  • Screw terminal connections

Description

The LE-HPS-SAH-WP Weatherproof Manual Pull Station is a UL Listed fire alarm initiating device suitable for applications requiring outdoor mounting of the manual fire alarm pull station. The LE-HPS-SAH-WP is appropriate for applications where the manual pull station may be subject to wet conditions. The LE-HPS-SAH-WP consists of a die-cast aluminium back box (LE-HPS-BB), Neoprene sealing gasket and a special manual fire alarm box. The unit is a high quality pull station constructed entirely of nontoxic materials with a low profile and rounded edges to fit most design requirements. All components are pre-painted, or have plated surfaces to inhibit corrosion.

MODULES

e.syline, the line of electronic water pressure booster systems that
redefines the rules of residential water pressurization.

M1.20

Fast Response Contact Module – LE-DCP-FRCMA/-I

Features

  • Single input contact monitor
  • Fast, reliable contact monitoring utilizing the DCP (Digital Communications Protocol)
  • Two different mounting configurations
  • 127 devices can be used per DCP loop
  • Bi-colored indicating LED provides module status (Both Models)
  • Yellow LED indicates a short circuit condition (LE-FRCMA-I only)
  • Can be programmed to monitor Normally Open (NO) or Normally Closed (NC) contacts inClass B
  • Operates on Class A or Class B SLC loop
  • Accepts up to 14 AWG wire
  • UL 864 Listed

Description

The LE-DCP-FRCMA/-I Fast Response Contact Monitoring Modules are designed to be used with pull stations, water flow switches, and other applications requiring the monitoring of dry contact alarm initiating devices. The interrupt driven Digital Communications Protocol (DCP) combines maximum communication reliability and fast response to emergency conditions. Two different mounting configurations are provided to meet a wide range of applications. The LE-DCP-FRCMA/-I contact monitoring module does not require a separate 24 VDC power source.

M1.21

Dual Relay Output Module – LE-DCP-R2ML/H-I

Features

  • Provides two independently configurable Form C contacts per address
  • Contacts are rated as follow:
    • LE-DCP-R2ML: 2A @ 30 VDC / 0.5A @ 120 VAC
    • LE-DCP-R2MH: 8A @ 30VDC / 4.8A @ 250 VAC
  • Up to127 devices can be used on each SLC loop
  • Visible Bi-colored LED is software controlled and can be programmed to blink red or green when polled. The LED can be latched on when activated. (For All Models)
  • Yellow LED indicates a short circuit condition (LE-DCP-R2ML-I & LE-DCP-R2MH-I only)
  • Programming is highly flexible providing 16 priority states plus zoning capability
  • Operates on Class A or Class B SLC loop
  • UL 864 Listed

Description

The Dual Relay Modules (LE-DCP-R2ML/H Series) have been designed to provide flexible and quick response to emergency conditions. The LE-DCP-R2ML/H Series allows independent control of two form C contacts for a variety of normally open and normally closed contact applications such as fan operation, elevator recall, door closure, and auxiliary notification

M1.22

Class A Supervised Output Module – LE-DCP-SOM-A/AI

Features

  • Built-in SCI circuitry (LE-DCP-SOM-AI only)
  • Flexible application
  • Quick response to emergency conditions
  • Operation parameters are maintained by the module, and individual communication with the control system during emergency conditions is not required
  • Contacts are rated 2.0 Amps @ 24VDC
  • Programming is highly flexible providing 16priority states plus zoning capability
  • Programmed device output is turned off, silenced, or programmed to output the selected pattern
  • UL 864 Listed

Description

The Class A Supervised Output Modules (LE-DCP-SOM-A & LE-DCP-SOM-AI) have been designed to provide application flexibility and quick response to emergency conditions. Flexibility is provided by a wide range of operating modes, including supporting multi-zone operations, and/ or functions, up to 16 different modulation patterns and multi-state programming. The operating parameters for the LE-DCP-SOM-A & -AI are maintained by the module and do not require individual communication with the control system during emergency conditions to operate. The control panel simply broadcasts system conditions on the Signaling Line Circuit (SLC) and the LE-DCP-SOM-A &-AI modules do the rest based upon the custom configuration. Each LE-DCP-SOM-A & -AI provides a single Class B or Class A circuit rated for 2.0 Amps @ 24VDC. Each LE-DCP-SOM-A &-AI also requires a 24 VDC power source in addition to the SLC.

M1.23

Supervised Output Module – LE-DCP-SOM-R

Features

  • UL 864 9th Edition Listed
  • Flexible Pre-Action application
  • Quick response to emergency conditions
  • Operation parameters are maintained by the module, and individual communication with the control system during emergency conditions is not required
  • Contacts are rated 2.0 Amps @ 24VDC
  • Programming is highly flexible providing 16 priority states plus zoning capability
  • Program status:
  • LED will flash red or green
  • Programmed device output is turned off, silenced, or programmed to active continuously

Description

The Supervised Output Module (LE-DCP-SOM-R) is designed for Single-Interlock Pre-Action sprinkler systems. During an alarm condition, the LE-DCP-SOM-R output will operate which will trip a solenoid valve, allowing water to fill the sprinkler system piping. Water is not discharged until a sprinkler head operates due to heat from the fire. Pre-Action systems provide an added level of protection against inadvertent water discharge and are frequently employed in water sensitive locations such as archival vaults, fine art storage rooms, rare book libraries and computer centers

M1.24

Key Switch Disable Module – LE-SOM-R-DS

Features

  • UL Listed
  • Physical switch provides NFPA-compliant disable solution for releasing service

Description

LE-SOM-R-DS is a double-pole single-throw disable switch used to disable a releasing circuit for system testing or maintenance. The LE-SOM-R-DS is compatible with LE-SOM-R addressable module and the Hawk Extinguishing Conventional Releasing Fire Alarm Control Panel. LE-SOM-R-DS is intended to be mounted to a single gang electrical box.

M1.25

Dual Input Monitoring Module – LE-DCP-DIMM

Features

  • UL 864 9th Edition Listed
  • Fast, reliable contact monitoring utilizing the DCP (Digital Communications Protocol)
  • 127 devices can be used per DCP loop
  • Bi-colored indicating LED provides module status
  • Dual input contact monitor
  • Can be programmed to monitor Normally Open (NO) or Normally Closed (NC) contacts
  • Operates on Class A or Class B SLC loop
  • Accepts up to 14 AWG wire

Description

The Dual Input Monitor Module (LE-DCP-DIMM) is designed for use on a UL listed Fire Alarm Control Panel. It provides two independent contact monitoring circuits while only utilizing one address on the SLC loop. Up to 127 devices can be placed on a single SLC loop. The device address is uniquely stored on an on-board EEPROM. The module can be programmed to monitor Normally Open (NO) or Normally Closed (NC) contact fire alarm and supervisory devices. The interrupt driven Digital Communication Protocol (DCP) combines maximum communication reliability and fast response to emergency conditions. The module has a single bi-colored LED to indicate device status. It fits into a standard 4″ square or double gang electrical back box.

M1.26

Conventional Zone Module – LE-DCP-CZM

Features

  • UL 864 9th Edition Listed
  • Provides an address point for a zone of up to 25 conventional smoke detectors
  • Blinks green when polled. Latched on red (controlled by panel) when activated
  • Device address can be programmed with a handheld programmer. Device address ranges from 1 to 127
  • Compatible with Class B and Class A wiring
  • Auxiliary power source provides power for the zone of detectors
  • Compatible with conventional detectors, LE-SLR, LE-SIJ, LE-SLV, LE-DCD, LE-DFE series
  • Compatible with TH series linear heat cables from Proline Protection Systems

Description

The Conventional Zone Module (LE-DCP-CZM) is designed for use on an analog addressable Fire Alarm system. Up to 127 devices can be placed on a single SLC loop. The device address is uniquely stored on an onboard EEPROM. The module allows the panel to interface and monitor two-wire conventional detectors or pull stations. Each LF-DCP-CZM transmits the status on one zone of devices (25 maximum per zone) back to the panel. It supervises the power supply as well as the entire zone of devices. Status conditions are reported as normal, open or alarm. All 2-wire smoke detectors must be UL listed as compatible to be interfaced with the LF-DCP-CZM. The interrupt driven Digital Communication Protocol (DCP) combines maximum communication reliability and fast response to emergency conditions. The module has a single bicolored LED to indicate device status. It fits into a standard 4″ square or double gang electrical back box.

M1.27

Short Circuit Isolator – LE-DCP-SCI

Features

  • Can be placed at any location on SLC loop
  • Checks the line for short circuit at power up. If the line is normal, the relay will be returned on. If a line short is detected, the relay remains open
  • Indication of a single short circuit by a yellow LED

Description

The LE-DCP-SCI short circuit isolator should be located between any devices on the SLC loop. In the event of a short on the SLC loop, the two adjacent isolators (closest isolators to the left and right of the shorted section) will activate and their respective LED indicators will be turned on. All devices between the active short circuit isolators will be dead. This will prevent entire loop failure. Upon removal of the short condition, the LE-DCP-SCIs will automatically restore, the entire loop to the normal operating state.

NOTIFICATION APPLIANCES

e.syline, the line of electronic water pressure booster systems that
redefines the rules of residential water pressurization.

M1.30

Selectable Candela Evacuation Signals – HEC3-24WR

Features

  • Nominal voltage – 24VDC
  • 24VDC units have field selectable candela options of 15, 30, 60, 75, and 110 candela
  • Unit Dimensions: 5″ high x 4.5″ wide x 2.5″ deep
  • Synchronize strobe and/or horn with Hochiki Series Control Module
  • Pre-wire entire system, then install signals
  • Lower installation and operating costs
  • Input terminals supports 12 to 18 gauge wire
  • Switch selection for high or low dBA
  • Switch for chime, whoop, mechanical and 2400Hz tone
  • Switch for continuous or temporal 3 (not available on whoop tone)
  • Surface mount with the HSB (Hochiki surface mount box)
  • Silence horn while strobes remain flashing
  • Wide voltage range  16-33VDC
  • Face-plate available in red

Description

The HEC3-24WR is a low profile horn/strobe combination that offers dependable audible and visual alarms and the lowest current available. It offers tamper-proof field selectable candela options of 15, 30, 60, 75, and 110 candela. The horn offers a continuous or synchable temporal three in 2400Hz and mechanical tone, a hime and whoop tone. All tones are easy for the professional to change in the field by using switches. It has a minimal operation current and has a minimum flash rate of 1Hz regardless of input voltage.It is shipped with a standard 4” metal mounting plate which incorporates the popular Slide feature that allows the installer to easily test for supervision. The product also features a locking mechanism which secures the product to the bracket without any screws showing. The HEC3-24WR appliances are UL 464 and UL 1971 listed for use with fire protective systems and are warranted for three years from date of purchase.

M1.31

Conventional Fire Alarm Bell – LFB16, LFB18 & LFB110

Features

  • Microprocessor based design
  • High dBA Sounds Output
  • Low power consumption
  • Available in 6″, 8″ 10″ Housing
  • Quickly and easily installed

Description

Fire Alarm Bells are specially designed for fire alarm applications. The bell gongs are made of alloy steel to give the loud tones necessary in fire alarm systems. It is available in three gong sizes for different applications. For weather-proof application offers an optional weatherproof back box.

PROJECT BEAM SMOKE DETECTOR

e.syline, the line of electronic water pressure booster systems that
redefines the rules of residential water pressurization.

m1.32

Projected Beam Smoke Detector – LE-SPC-24

Features

  • Microprocessor based for reliability
  • Simple setup & alignment with signal strength LED’s
  • Provides 60 feet on center linear protection at a range of 32.8 feet to 328 feet
  • Automatic compensation for signal drift or dirty lens
  • Three field adjustable sensitivity settings
  • Form A alarm and Form B trouble contacts
  • Calibrated filters available to verify sensitivity
  • Color-coded emitter and receiver labels for easy recognition
  • Adjustable to one of the three obscuration settings of 25%, 50% or 70% per span
  • Voltage and RF transient protection
  • External red LED when alarm condition is indicated.

Description

The LE-SPC-24 Projected Beam Smoke Detector consists of an emitter and receiver. The projected beam smoke detector should be placed so that smoke generated by a fire will likely rise into the path of the beam. The receiver is constantly monitoring and measuring the intensity of the beam transmitted by the emitter. Should the smoke from a fire cause a decrease in the signal strength of a magnitude that exceeds the programmed obscuration setting, an alarm signal is generated. The LE-SPC-24 Projected Beam Smoke Detector can provide vital fire detection in applications where other types of detectors may not be able to respond quickly, or at all, to a fire condition.

ADDRESSABLE MANUAL PULL STATIONS

e.syline, the line of electronic water pressure booster systems that
redefines the rules of residential water pressurization.

M1.33

Addressable Manual Pull Stations – LE-DCP-AMS

Features

  • Addressable integrated design
  • All metal construction
  • Single and dual action models available
  • Extremely easy to operate
  • Bi-colored status LED indicates Standby and Alarm conditions
  • Address is programmable in EEPROM
  • Address can be programmed when installed
  • Key lock or hex key lock models available
  • Enclosed switch with glass rod (included)
  • Terminals accept up to 14AWG wire
  • Surface mount back box available

Description

The LE-DCP-AMS are the series of addressable manual pull stations that provide a fast and practical means of manually initiating a fire alarm signal. Both single action and dual action manual pull stations are available. Resetting of the pull station requires either a Cat 30 key or a 1/8″ hex key (depending upon the model used). An alarm condition is actuated by pulling down on the handle of the LE-DCP-AMS and LE-DCP-AMS-KL single action models. On the dual action models LE-DCP-AMS-LP and LE-DCP-AMS-KL-LP the Lift and Pull cover must be lifted before pulling down on the pull station handle. Once the pull station is activated, the handle cannot be put back into a normal standby condition without using the key operated reset feature. The LE-DCP-AMS series is electronically addressable and includes a bi-colored status LED. The LED blinks green indicating normal communication with the DCP compatible SLC loop. When an alarm condition is actuated by pulling the handle, the LED will latch Red to indicate the alarm condition.